Wonsun Machinery & Electrical Technology Co. Ltd
|
Gold Index: 12593
Place of Origin: | Zhejiang, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
Remote Control Automatic Barrier Gate Free Logo For Access Control
Specifications
Mode:WST116
Working Temperature:-40+75
Voltage:220V±10%, 110V±10%, 50/60HZ
Rated power:80W
Relative humidity:≤90%
Remote control distance:≥30m
Net weight:48kg
Speed:0.6s,1s,1.8s,3s,4s,6s.
Max boom length:8 meters
Motor rotational speed:1400rmp
Protection degree:IP44
Basic Features:
1) By-security. the barrier gate will automatically go back when meet obstacles during closing. |
2) AC motor is more powerful and no maintenance. |
3) Barrier Boom/arm can be chosen from 3 meters to 6 meters, and barrier gate. |
4) Closing time is also arranged from 1 second to 6 seconds. |
5) The barrier gate can be both right-installed and left-installed. |
6) All the operation process is soft without any noise and shaking. |
7) Infrared photocell interface, loop detector interface and IC system. |
8) interface are reserved for the other functions. |
9) Green light and red light are used inside for indication the position of the boom |
Advanced Features:
1) clutch key can be used to open the clutch when power off. |
2) Fan cooling machine reduce the motor temperature by high frequency using, never get heat-protecting, unique temperature calefaction design for low temperature using, prevent freezing in cold weather. |
3) Exactitude aluminium alloy die-casting motor base reduce the noise and joint abrasion to prolong the barrier gate working life. |
Communication with customers
1) Q: Connected power and press open/close button but traffic barrier gate no action?
A |
Reason |
Solution |
1 |
Fuse blown |
Check fuse and power in controller |
2 |
Battery of remote control powered off |
Change a new one |
3 |
External protection circuit break or at protecting status |
Open the barrier door and click OPEN/CLOSE button on control box |
4 |
Same frequency interference |
Check photocell and loop detector |
2) Q:Connected power and press open/close button,traffic barrier gate will move but even when
it is at right position, the motor still running and not stop?
A |
Reason |
Solution |
1 |
Limit switch |
Adjust the horizontal/vertical limit switch to correct position |
2 |
Main controller failure |
Change a new one |
3) Q: Motor running but traffic barrier gate arm no action?
A |
Reason |
Solution |
1 |
Barrier arm at 45° position where is hard to move |
Unlock clutch and manually rotate arm to horizontal or vertical position then try again |
2 |
Tension of balancing spring not suitable |
Wonsun Machinery & Electrical Technology Co. Ltd [China (Mainland)]
Business Type:Manufacturer |